NCT02790437

A Phase II Study to Evaluate the Efficacy of IdeS to Desensitize Transplant Patients With a Positive Crossmatch Test

Hansa Biopharma AB · Phase 2 · COMPLETED

Enrollment
19
Study start
Jun 2016
Primary completion
Dec 12, 2017
ACTUAL

Registered primary endpoints

Number of Patients With Crossmatch Conversion (Positive to Negative)

IdeS ability to create a negative crossmatch (XM) test in patients who before treatment exhibit Donor Specific Antibodies (DSAs) and have a positive XM test to their available live or deceased donor kidney. XM was assessed using both FACS and CDC XM tests. FACS XM is a multi-staining procedure where the recipient's serum is used to stain donor cells to identify presence of DSAs in recipient's serum. T- and B-cells are identified using conjugated antibodies against CD3 and CD19. DSAs are identified using a conjugated anti-human antibody. CDC XM evaluates the cytotoxic capacity of the DSAs. The recipient's serum is mixed with donor cells prior to addition of complement. Fluorescent dyes are added and the live/dead cells (%) is scored using a fluorescent microscope. CDC XM amplified with anti-human globulin is not compatible with imlifidase and should not be used. The endpoint was met if at least one XM test was positive pre-dose and the last test within 24 h was negative.

Time frame: Within 24 hours of IdeS dosing

Linked assets

Original registry record

ClinicalTrials.gov · NCT02790437

Registry last update: May 20, 2021 · Retrieved Nov 23, 2026